TD series X-ray analyzer
X-ray analyzer
X-ray diffractometer is one kind of the X-ray analyzer.
X-ray diffractometer can be installed many accessories to be the special function X-ray diffractometer.
TXZ-7 Rotating Sample Stage (Options)
It can eliminate the factor of the differences in sample preparation. And it ensures the good reproducibility of diffraction intensity. The use of movingθaxis can be crystal orientation.
TZY-12 instrument of producing sample
It is used for the production of powder samples. The uniformity of the sample is good.
TXZ-10 instrument of swapping sample
It is droved by the imported stepper motor and controlled by the imported programmable controller .It doesn’t need people to swap the sample. The sample is tested by the system automatically and continuously. And the data is kept by the system automatically.
TD series X-ray diffractometer technical parameters
Name | Items | TD-2500 | TD-3000 | TD-3500 | ||||
X-ray tube (domestic or import) | Type | Tube voltage 60kV(target arbitrary choice Cu.Fe.Co.Cr.Mo) | ||||||
Focus size | 1×10mm2 | 1×10mm2 or 0.4×14mm2 | ||||||
Maximum output power | 2.0kW | 2.4 kW or 2.7 kW | ||||||
X-ray Generator
| Control mode | Microcomputer automatic 1Kv/step 1mA/step | ||||||
Maximum output power | 5kW
| |||||||
X-ray tube voltage | 10-60kV | |||||||
X-ray tube current | 5-80mA | 2-80mA | ||||||
Stability | <0.01% | |||||||
Alarm device | There are Kv too high,Kv too lower,mA too high,mA too lower,no water,X-ray tube over-temperature, machine over-current protection and X-ray tube power protection etc. | |||||||
Goniometer | structure | horizontal(θ-2θ) | vertical(θ-2θ) | Sample levelθs-θd | ||||
Goniometer scanning radius | 185mm(150~285mm adjustable) | |||||||
Scanning range | 0°~164°(2θ) | -35°~170° | -35°~170°(measuring range) | |||||
-180°~180°(θ) | -35°~85°(θs/θd linkage) -35°~170°(θs/θd single action) | |||||||
Scanning speed | 0.06°-76.2°/min | 0.006°-96°/min | ||||||
Scanning mode | θ-2θ linkage,θ, 2θ single action,continuous or step scanning | θs/θd linkage, single action
| ||||||
Minimum step angle | 0.001° | 0.0001° | ||||||
Measuring accuracy | ≤0.005° | ≤0.001° | ||||||
Angle positioning speed | 120°/min | 1000°/min | ||||||
2θ repeatability accuracy | ≤0.001° | ≤0.0005° | ||||||
Recording/ Control Unit | counter | Proportional (PC) or scintillation(SC) | ||||||
Maximum linear count rate | 5×106CPS | 1×107CPS | ||||||
Spectrum resolution(Cu.kα spectrum linear) | ≤25%(PC)or≤60%(SC) | ≤20%(PC)or≤50%(SC) | ||||||
Counter high voltage | 0-2100V or 0-1100V continuously adjustable | |||||||
Counter mode | PLC automatic control differential integral mode conversion,automatic PHA,dead time correction | |||||||
Detector high voltage stability | Excel ±0.01% | Excel ±0.005% | ||||||
x-ray leakage | less than 0.1 μSv/h | |||||||
aggregative indicator | Safety indicators | Protection system for double protection, have a big and a small shield, to ensure the safety of the users | ||||||
Integrated stability | ≤0.5% | ≤0.3% | ||||||
Overall dimensions | 1100×920×1750mm | |||||||
TD series X-ray analyzer