- Contact Person : Ms. wang Helen
- Company Name : Dandong Tongda Science & Technology Co., Ltd.
- Tel : 86-0415-6153617
- Fax : 86-0415-6153217
- Address : Liaoning,dandong,Jixian Street, Zhenxing District, Dandong, No. 17
- Country/Region : China
- Zip : 118303
TD series X-ray Product
X-ray product is appied widely now.It includes X-ray analysis equipment and X-ray NDT equipment.
X-ray analysis equipment includes X-ray diffractometer,X-ray crystal analysis equipment and X-ray crystal direction finder.
TD series XRD characteristics:
*the tertiary non-disturbance isolation protection,
*the performance is more superior,
*the failure rate is extremely low,
*the complete machine service life is long,
*the design is precise,
*the hardware and the software function is complete,
*can adapt the test of material microscopic structure, the analysis and the research work nimbly.
TD series X-ray diffractometer technical parameters
Name | Items | TD-2500 | TD-3000 | TD-3500 | ||||
X-ray tube (domestic or import) | Type | Tube voltage 60kV(target arbitrary choice Cu.Fe.Co.Cr.Mo) | ||||||
Focus size | 1×10mm2 | 1×10mm2 or 0.4×14mm2 | ||||||
Maximum output power | 2.0kW | 2.4 kW or 2.7 kW | ||||||
X-ray Generator
| Control mode | Microcomputer automatic 1Kv/step 1mA/step | ||||||
Maximum output power | 5kW
| |||||||
X-ray tube voltage | 10-60kV | |||||||
X-ray tube current | 5-80mA | 2-80mA | ||||||
Stability | <0.01% | |||||||
Alarm device | There are Kv too high,Kv too lower,mA too high,mA too lower,no water,X-ray tube over-temperature, machine over-current protection and X-ray tube power protection etc. | |||||||
Goniometer | structure | horizontal(θ-2θ) | vertical(θ-2θ) | Sample levelθs-θd | ||||
Goniometer scanning radius | 185mm(150~285mm adjustable) | |||||||
Scanning range | 0°~164°(2θ) | -35°~170° | -35°~170°(measuring range) | |||||
-180°~180°(θ) | -35°~85°(θs/θd linkage) -35°~170°(θs/θd single action) | |||||||
Scanning speed | 0.06°-76.2°/min | 0.006°-96°/min | ||||||
Scanning mode | θ-2θ linkage,θ, 2θ single action,continuous or step scanning | θs/θd linkage, single action
| ||||||
Minimum step angle | 0.001° | 0.0001° | ||||||
Measuring accuracy | ≤0.005° | ≤0.001° | ||||||
Angle positioning speed | 120°/min | 1000°/min | ||||||
2θ repeatability accuracy | ≤0.001° | ≤0.0005° | ||||||
Recording/ Control Unit | counter | Proportional (PC) or scintillation(SC) | ||||||
Maximum linear count rate | 5×106CPS | 1×107CPS | ||||||
Spectrum resolution(Cu.kα spectrum linear) | ≤25%(PC)or≤60%(SC) | ≤20%(PC)or≤50%(SC) | ||||||
Counter high voltage | 0-2100V or 0-1100V continuously adjustable | |||||||
Counter mode | PLC automatic control differential integral mode conversion,automatic PHA,dead time correction | |||||||
Detector high voltage stability | Excel ±0.01% | Excel ±0.005% | ||||||
x-ray leakage | less than 0.1 μSv/h | |||||||
aggregative indicator | Safety indicators | Protection system for double protection, have a big and a small shield, to ensure the safety of the users | ||||||
Integrated stability | ≤0.5% | ≤0.3% | ||||||
Overall dimensions | 1100×920×1750mm | |||||||
TD series X-ray Product